Identifying a CJC-1295-labeled preparation with high-resolution mass spectrometry

A forensic laboratory investigated an unknown peptide preparation instead of trusting its label.

Analytical studyPaper year: 2010CJC-1295-labeled preparation

01 / DESIGN

What was studied?

An unknown preparation submitted to a laboratory was examined using liquid chromatography and high-resolution tandem mass spectrometry. The investigators interpreted fragmentation data to propose an amino-acid sequence and a terminal modification.

02 / FINDINGS

What did the researchers report?

They identified a 29-amino-acid peptide with a C-terminal amide and discussed its consistency with material marketed as CJC-1295. The paper illustrates how analytical identity can be investigated independently of marketing terminology.

03 / LIMITS

How should it be interpreted?

This is a single analytical investigation, not a clinical trial or a survey of all products. A proposed sequence does not establish purity, sterility, net content or equivalence to an albumin-binding clinical analogue. The original methods and reference materials matter when interpreting identity claims.

Loti Labs Peptide editorial reading note. Based on the linked source record. Methods and corrections.